multi-PHOT® is the first multi-photometer.
The operator can work with up to 4 simultaneous workstations.
The complimentary multi-PHOT Manager® software allows to manage up to 4 analyzers at the same time, to collect different test results, to print patient reports, and to perform quality control charts.
Light Source
• Quarz-halogen lamp 6V-10W
• Long life
Wavelength Range
• Automatic with 8 positions filter-wheels
• 6 standard interference filters: 340, 405, 505, 546, 578 and 620 nm.
• 2 positions free.
Photometric Range
• 0 to 2,5 Absorbance
• Linearity up to 2,0 Absorbance
Detector
• Photo diode (320-1000) nm.
Blanking
• Automatic zero setting.ADC
• ADC converter: 16 Bit
Operator Interface
• User friendly software for PC with Windows ® platform;
• Stand alone functioning.
Results Backup
• Automatic backup of all results into database;
• Easy access to historical data.
Measurement Procedures
• Kinetic, with linearity check, with or without reagent blank;
• Initial rate, with or without reagent blank;
• End point, with or without reagent blank;
• Bichromatic, with or without reagent blank;
• Sample blank, with or without reagent blank.
Measuring Time
• Programmable, 2 to 998 seconds for kinetic and two points type of tests;
• For end point, fixed at 2 seconds.
Delay Time
• Programmable, 0 to 999 seconds.
Flow Cell
• Glass, measuring volume 35µl.
• Carryover : < 1%
Aspirator System
• Internal peristaltic pump, drived by stepper motor;
• Back panel connection for waste;
• Aspiration volume programmable.
Power Requirements
• 100-200 VAC nominal, 50-60 Hz;
Calibration
• Factor, one-point, two-points and multi-points;·1 standard (linear mode);
• multi standards (non linear mode).
• Possibility to choose the best fitting curve between linear, polynomial, 4-parameter, spline, Log/logit
Method Parameter Settings
• Test code;
• Test name;
• Units for results;
• Decimal figures;
• Levels for flagging (man and woman);
• Measurement method;
• Wavelenght 1 and 2;
• Sample volume;
• Reagent volume;
• Measurement time;
• Delay time;
• Factor;
• Concentrations standards;
• Reagent blank y/n;
• Linearity;
• Number of controls used;
• Formula (for combinations of tests).
Quality Control
• One or Two controls per test;
• Control materials management;
• QC survey of all control measurement;
• Levey-Jenning chart;
• Youden plot chart;
• High/Low flags.
• Backup automatic of QC data history. (Automatic backup)
Temperature Control
• Fixed temperature at 37°C
Warm-Up Time
• Less of 5 minutes
Printer
• Automatic PDF documents generated by software;
• Internal thermal printer for stand alone use.
Display
• 4 x 20 characters with blue led backlight
Keyboard
• 5 keys for stand alone use
Signal Interface
• USB port for PC connection;
• Wireless connection.
Quality Approvals
• CE.
Dimensions
• H: 370 mm; W: 190 mm; D: 420 mm
Weight
• 10 Kg
Room temperatures
• 15 to 30°C
Range of Humidity
• 45 -85% not condensed